Optimization of inhomogeneous magnetization transfer (ihMT) MRI contrast for preclinical studies using dipolar relaxation time (T1D) filtering - CNRS - Centre national de la recherche scientifique Accéder directement au contenu
Article Dans Une Revue NMR in Biomedicine Année : 2017

Optimization of inhomogeneous magnetization transfer (ihMT) MRI contrast for preclinical studies using dipolar relaxation time (T1D) filtering

Résumé

A pulsed inhomogeneous magnetization transfer (ihMT)-prepared fast imaging sequence was implemented at 11.75 T for preclinical studies on mouse central nervous system. A strategy based on filtering the ihMT signal originating from short dipolar relaxation time (T1D) components is proposed. It involves increasing the repetition time of consecutive radiofrequency (RF) pulses of the dual saturation and allows improved signal specificity for long T1D myelinated structures. Furthermore, frequency offset, power and timing saturation parameters were adjusted to optimize the ihMT sensitivity. The optimization of the ihMT sensitivity, whilst preserving the strong specificity for the long T1D component of myelinated tissues, allowed measurements of ihMT ratios on the order of 4–5% in white matter (WM), 2.5% in gray matter (GM) and 1–1.3% in muscle. This led to high relative ihMT contrasts between myelinated tissues and others (~3–4 between WM and muscle, and ≥2 between GM and muscle). Conversely, higher ihMT ratios (~6–7% in WM) could be obtained using minimal T1D filtering achieved with short saturation pulse repetition time or cosine-modulated pulses for the dual-frequency saturation. This study represents a first stage in the process of validating ihMT as a myelin biomarker by providing optimized ihMT preclinical sequences, directly transposable and applicable to other preclinical magnetic fields and scanners. Finally, ihMT ratios measured in various central nervous system areas are provided for future reference.

Mots clés

Fichier principal
Vignette du fichier
NMRBiomed2017_HAL.pdf (2.51 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-01657969 , version 1 (24-01-2022)

Identifiants

Citer

V. H. Prevost, O. M. Girard, S. Mchinda, G. Varma, D. C. Alsop, et al.. Optimization of inhomogeneous magnetization transfer (ihMT) MRI contrast for preclinical studies using dipolar relaxation time (T1D) filtering. NMR in Biomedicine, 2017, 30 (6), ⟨10.1002/nbm.3706⟩. ⟨hal-01657969⟩
62 Consultations
26 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More